Skip to main content

Hydrophone Input Interface

Overview​

The two Hydrophone Input Interface connectors digitize acoustic data from up to eight hydrophones in addition to the standard acoustic transducer interface.

Electrical Connections​

Each hydrophone input is single-ended; the AINxN returns are tied internally to board ground. Each input is AC-coupled through a 10,000 pF capacitor with a 158 kΩ resistor, producing a 100 Hz high-pass cutoff and approximately 158 kΩ pass-band input impedance.

On PMM6081 units manufactured before mid-2026, odd-numbered inputs (AIN1, AIN3, AIN5, and AIN7) default to 43 dB gain and even-numbered inputs default to 12 dB. On units manufactured after mid-2026, all hydrophone inputs default to 43 dB gain.

The full-scale ADC input is 5.32 V peak-to-peak. This corresponds to 37.3 mV peak-to-peak at a 43 dB input and 1.34 V peak-to-peak at a 12 dB input. Contact info@popotomodem.com for other gain configurations.

Refer to the digital board connector locations figure for the connectors' physical locations.

PMM6081 hydrophone input interface schematic
Hydrophone Input Interface schematic connections.
Hydrophone Input Connector 1 Interface Electrical Pinout
Pin NumberI/OPin NameNotes
1IAIN4PHydrophone input
2PAIN4NHydrophone return
3IAIN3PHydrophone input
4PAIN3NHydrophone return
5IAIN2PHydrophone input
6PAIN2NHydrophone return
7IAIN1PHydrophone input
8PAIN1NHydrophone return
9PVSYS_5V+5 V out when unit is powered up
10PGNDBoard ground
Hydrophone Input Connector 2 Interface Electrical Pinout
Pin NumberI/OPin NameNotes
1IAIN8PHydrophone input
2PAIN8NHydrophone return
3IAIN7PHydrophone input
4PAIN7NHydrophone return
5IAIN6PHydrophone input
6PAIN6NHydrophone return
7IAIN5PHydrophone input
8PAIN5NHydrophone return
9PVSYS_5V+5 V out when unit is powered up
10PGNDBoard ground

Hardware Components​

Each Hydrophone Input Interface uses a Molex iGrid connector, P/N 5016461000, or equivalent. The recommended contacts are Molex P/N 5016471000, suitable for 22–26 AWG wire. They can be crimped with Molex hand tool 0638192300; pre-crimped leads may also be used.

Molex iGrid ten-position connectorMolex iGrid housing pin numbering
Hydrophone Input Interface User-Side Molex Connector.
Hydrophone Input Interface Components and Part Numbers
Part NumberManufacturerDescription
5016461000MolexiGrid 10-position connector receptacle, 2.0 mm pitch
5016471000MolexiGrid 22–26 AWG sockets
0638192300MolexiGrid 22–26 AWG hand crimp tool
2174912225MolexPre-crimped iGrid 22 AWG lead, 450 mm length

Mating Cable Notes​

  • Route all hydrophone connections carefully to minimize noise pickup.
  • Attach or detach the interface only while power is disconnected from the OEM modem to avoid electrical damage.