RS-232 Interface
Overview
The RS-232 Interface is a single connector providing the two signals required for full-duplex RS-232 communication with the OEM modem.
Electrical Connections
All signal directions are relative to the OEM modem. Refer to the top connector locations figure for the physical location of the connector.

| Pin Number | I/O | Pin Name | Notes |
|---|---|---|---|
1 | I | RS-232 RX | RS-232 receive |
2 | O | RS-232 TX | RS-232 transmit |
3 | I | RS232_INT_EXT | General-purpose digital input or 1PPS; +1.8 V to +5 V logic level |
4 | - | NC | No connection on modem |
Hardware Components
The RS-232 Interface uses the same Molex PicoBlade connector components as the RS-422 Interface.


| Part Number | Manufacturer | Description |
|---|---|---|
0510210400 | Molex | PicoBlade 4-position connector receptacle, 1.25 mm pitch |
0500798000 | Molex | PicoBlade 26–28 AWG sockets |
2002181900 | Molex | PicoBlade hand crimp tool |
2149202211 | Molex | Pre-crimped PicoBlade lead, 75 mm length |
Mating Cable Notes
Attach or detach the interface only while power is disconnected from the OEM modem.