RS-422 Interface
Overview
The RS-422 Interface is a single connector providing the two differential pairs required for full-duplex RS-422 communication with the OEM modem.
Electrical Connections
All signal directions are relative to the OEM modem. Refer to the top connector locations figure for the physical location of the connector.

| Pin Number | I/O | Pin Name | Notes |
|---|---|---|---|
1 | O | RS-422 TX+ | RS-422 transmit positive |
2 | O | RS-422 TX- | RS-422 transmit negative |
3 | I | RS-422 RX+ | RS-422 receive positive |
4 | I | RS-422 RX- | RS-422 receive negative |
Hardware Components
The RS-422 Interface uses a Molex PicoBlade connector, P/N 0510210400, or equivalent. The recommended contacts are Molex P/N 0500798000, suitable for 26–28 AWG wire. They can be crimped with Molex hand tool 2002181900, or pre-crimped wires may be used.


| Part Number | Manufacturer | Description |
|---|---|---|
0510210400 | Molex | PicoBlade 4-position connector receptacle, 1.25 mm pitch |
0500798000 | Molex | PicoBlade 26–28 AWG sockets |
2002181900 | Molex | PicoBlade hand crimp tool |
2149202211 | Molex | Pre-crimped PicoBlade lead, 75 mm length |
Mating Cable Notes
- Mating cables must use twisted-pair wiring for pins
1/2and3/4. - Attach or detach the interface only while power is disconnected from the OEM modem.