The RS-422 Interface is a single connector providing the two differential pairs required for full-duplex RS-422 communication with the OEM modem.

Electrical Connections​

All signal directions are relative to the OEM modem. Refer to the top connector locations figure for the physical location of the connector.

PMM4511 RS-422 interface schematic
RS-422 schematic connections.
RS-422 Electrical Pinout
Pin NumberI/OPin NameNotes
1ORS-422 TX+RS-422 transmit positive
2ORS-422 TX-RS-422 transmit negative
3IRS-422 RX+RS-422 receive positive
4IRS-422 RX-RS-422 receive negative

Hardware Components​

The RS-422 Interface uses a Molex PicoBlade connector, P/N 0510210400, or equivalent. The recommended contacts are Molex P/N 0500798000, suitable for 26–28 AWG wire. They can be crimped with Molex hand tool 2002181900, or pre-crimped wires may be used.

Molex PicoBlade four-position connectorMolex PicoBlade housing pin numbering
RS-422 Interface user-side Molex connector.
RS-422 Interface Components and Part Numbers
Part NumberManufacturerDescription
0510210400MolexPicoBlade 4-position connector receptacle, 1.25 mm pitch
0500798000MolexPicoBlade 26–28 AWG sockets
2002181900MolexPicoBlade hand crimp tool
2149202211MolexPre-crimped PicoBlade lead, 75 mm length

Mating Cable Notes​

  • Mating cables must use twisted-pair wiring for pins 1/2 and 3/4.
  • Attach or detach the interface only while power is disconnected from the OEM modem.